Files
ACP/DeviceEditModule/ViewModels/S7200ViewModel.cs
T

145 lines
7.1 KiB
C#

using DeviceCommand.Devices;
using Prism.Commands;
using Prism.Ioc;
using System;
using System.Threading;
using System.Threading.Tasks;
using System.Windows.Input;
using UIShare.GlobalVariable;
using UIShare.ViewModelBase;
namespace DeviceEditModule.ViewModels
{
/// <summary>
/// S7200 高压直流源载一体机 控制面板 ViewModel
/// </summary>
public class S7200ViewModel : NavigateViewModelBase, IDisposable
{
private readonly DeviceManager _dm;
private S7200? _dev;
private CancellationTokenSource? _cts;
private string _deviceName = "S7200";
public string DeviceName { get => _deviceName; set => SetProperty(ref _deviceName, value); }
private bool _isConnected;
public bool IsConnected { get => _isConnected; set => SetProperty(ref _isConnected, value); }
private bool _isBusy;
public bool IsBusy { get => _isBusy; set => SetProperty(ref _isBusy, value); }
#region 输入参数
private double _voltage; public double Voltage { get => _voltage; set => SetProperty(ref _voltage, value); }
private double _current; public double Current { get => _current; set => SetProperty(ref _current, value); }
private double _cvPosI = 10; public double CvPosI { get => _cvPosI; set => SetProperty(ref _cvPosI, value); }
private double _cvNegI = -10; public double CvNegI { get => _cvNegI; set => SetProperty(ref _cvNegI, value); }
private double _ovpValue; public double OvpValue { get => _ovpValue; set => SetProperty(ref _ovpValue, value); }
private double _ocpValue; public double OcpValue { get => _ocpValue; set => SetProperty(ref _ocpValue, value); }
#endregion
#region 测量结果
private double _measuredVoltage;
public double MeasuredVoltage { get => _measuredVoltage; set => SetProperty(ref _measuredVoltage, value); }
private double _measuredCurrent;
public double MeasuredCurrent { get => _measuredCurrent; set => SetProperty(ref _measuredCurrent, value); }
private double _measuredPower;
public double MeasuredPower { get => _measuredPower; set => SetProperty(ref _measuredPower, value); }
private string _responseLog = "";
public string ResponseLog { get => _responseLog; set => SetProperty(ref _responseLog, value); }
#endregion
#region 命令
public ICommand QueryIdn { get; } public ICommand OutOn { get; } public ICommand OutOff { get; }
public ICommand SetRemote { get; } public ICommand ClearProt { get; }
public ICommand SetV { get; } public ICommand SetCC { get; } public ICommand SetCVPos { get; } public ICommand SetCVNeg { get; }
public ICommand SetOVP { get; } public ICommand SetOCP { get; }
public ICommand QMeas { get; }
#endregion
public S7200ViewModel(IContainerProvider cp) : base(cp)
{
_dm = cp.Resolve<DeviceManager>();
QueryIdn = new DelegateCommand(async () => await Exec(async () => Log("IDN:" + await _dev!.查询设备信息(Ct()))));
OutOn = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置通道开关(true, Ct()); Log("输出已开启"); }));
OutOff = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置通道开关(false, Ct()); Log("输出已关闭"); }));
SetRemote = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置为远程模式(Ct()); Log("远程控制"); }));
ClearProt = new DelegateCommand(async () => await Exec(async () => { await _dev!.清除保护状态(Ct()); Log("保护已清除"); }));
SetV = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置电压(Voltage, Ct()); Log($"电压={Voltage}V"); }));
SetCC = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置CC模式电流(Current, Ct()); Log($"CC电流={Current}A"); }));
SetCVPos = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置CV正向电流(CvPosI, Ct()); Log($"CV正向电流={CvPosI}A"); }));
SetCVNeg = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置CV反向电流(CvNegI, Ct()); Log($"CV反向电流={CvNegI}A"); }));
SetOVP = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置电压保护OVP电压(OvpValue, Ct()); Log($"OVP={OvpValue}V"); }));
SetOCP = new DelegateCommand(async () => await Exec(async () => { await _dev!.设置电流保护OCP电流(OcpValue, Ct()); Log($"OCP={OcpValue}A"); }));
QMeas = new DelegateCommand(async () => await Exec(async () =>
{
MeasuredVoltage = await _dev!.查询实时电压(Ct());
MeasuredCurrent = await _dev!.查询实时电流(Ct());
MeasuredPower = await _dev!.查询功率(Ct());
Log($"测量→V:{MeasuredVoltage} I:{MeasuredCurrent} P:{MeasuredPower}");
}));
Initialize();
}
#region 初始化 / Navigation
public void Initialize(string? deviceName = null)
{
S7200? found = null; string? fn = null;
if (deviceName != null && _dm.DeviceMap.TryGetValue(deviceName, out var d) && d is S7200 e)
{ found = e; fn = deviceName; }
else
{
foreach (var kv in _dm.DeviceMap)
if (kv.Value is S7200 it) { found = it; fn = kv.Key; break; }
}
_dev = found;
DeviceName = fn ?? "S7200 (未找到)";
IsConnected = _dev?.IsConnected ?? false;
Log(found != null
? $"已关联设备 [{DeviceName}],连接:{(IsConnected ? "已连接" : "未连接")}"
: "未在 DeviceManager 中找到 S7200 设备");
}
public override void OnNavigatedTo(NavigationContext context)
{
var pName = context.Parameters.GetValue<string?>("DeviceName");
Initialize(pName);
}
#endregion
#region 辅助
private CancellationToken Ct() => (_cts = new CancellationTokenSource(TimeSpan.FromSeconds(10))).Token;
private async Task Exec(Func<Task> action)
{
if (_dev == null) { Log("错误:未关联到设备实例,请检查设备配置。"); return; }
if (IsBusy) return;
IsBusy = true;
try
{
await action();
IsConnected = _dev.IsConnected;
}
catch (OperationCanceledException) { Log("命令超时或已取消。"); }
catch (Exception ex) { Log($"错误:{ex.Message}"); }
finally { IsBusy = false; }
}
private void Log(string message)
{
var line = $"[{DateTime.Now:HH:mm:ss}] {message}";
ResponseLog = ResponseLog.Length > 4000
? line + "\n" + ResponseLog[..3000]
: line + "\n" + ResponseLog;
}
#endregion
public void Dispose()
{
_cts?.Cancel();
_cts?.Dispose();
}
}
}