using System.Collections.ObjectModel;
using System.IO.Ports;
using System.Linq;
using System.Windows.Input;
using UIShare.PubEvent;
using UIShare.UIViewModel;
using UIShare.ViewModelBase;
namespace SettingModule.ViewModels.Dialogs
{
/// <summary>
/// 串口连接配置对话框 VM。
/// 通过 DialogParameters 接收宿主 DeviceInfoVM保存时把副本写回宿主。
/// </summary>
public class SerialPortConfigViewModel : DialogViewModelBase
{
#region
private string _title = "串口连接配置";
public string Title
{
get => _title;
set => SetProperty(ref _title, value);
}
private SerialPortConfigVM _config = new();
public SerialPortConfigVM Config
{
get => _config;
set => SetProperty(ref _config, value);
}
/// <summary>当前可用串口列表OnDialogOpened 刷新)。</summary>
public ObservableCollection<string> AvailablePorts { get; } = new();
public ObservableCollection<int> CommonBaudRates { get; } = new()
{
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800, 921600
};
public ObservableCollection<int> DataBitsList { get; } = new() { 5, 6, 7, 8 };
public ObservableCollection<string> StopBitsList { get; } = new()
{
"One", "OnePointFive", "Two"
};
public ObservableCollection<string> ParityList { get; } = new()
{
"None", "Odd", "Even", "Mark", "Space"
};
public ObservableCollection<int> CommonTimeouts { get; } = new()
{
500, 1000, 2000, 3000, 5000, 10000
};
private string _errorMessage = string.Empty;
public string ErrorMessage
{
get => _errorMessage;
set => SetProperty(ref _errorMessage, value);
}
#endregion
#region
public ICommand SaveCommand { get; }
public ICommand CancelCommand { get; }
public ICommand RefreshPortsCommand { get; }
#endregion
private DeviceInfoVM? _hostDevice;
public SerialPortConfigViewModel(IContainerProvider containerProvider) : base(containerProvider)
{
SaveCommand = new DelegateCommand(OnSave);
CancelCommand = new DelegateCommand(OnCancel);
RefreshPortsCommand = new DelegateCommand(RefreshPorts);
}
private void RefreshPorts()
{
AvailablePorts.Clear();
// 若当前选中的串口不在可用列表中,仍保留显示,便于离线编辑
if (!string.IsNullOrEmpty(Config.PortName) && !AvailablePorts.Contains(Config.PortName))
AvailablePorts.Insert(0, Config.PortName);
}
private bool Validate(out string error)
{
error = string.Empty;
if (string.IsNullOrWhiteSpace(Config.PortName))
{
error = "串口名称不能为空";
return false;
}
if (Config.BaudRate <= 0)
{
error = "波特率必须大于 0";
return false;
}
if (Config.DataBits < 5 || Config.DataBits > 8)
{
error = "数据位必须在 5 - 8 之间";
return false;
}
if (Config.ReadTimeout < 0 || Config.WriteTimeout < 0)
{
error = "超时时间不能为负数";
return false;
}
return true;
}
private void OnSave()
{
if (!Validate(out var error))
{
ErrorMessage = error;
return;
}
ErrorMessage = string.Empty;
if (_hostDevice != null)
{
_hostDevice.SerialPortConfig ??= new SerialPortConfigVM();
Config.CopyTo(_hostDevice.SerialPortConfig);
_hostDevice.ConnectionType = "Serial";
}
RequestClose.Invoke(ButtonResult.OK);
}
private void OnCancel() => RequestClose.Invoke(ButtonResult.Cancel);
#region Prism Dialog
public override void OnDialogOpened(IDialogParameters parameters)
{
_eventAggregator.GetEvent<OverlayEvent>().Publish(true);
if (parameters.ContainsKey("Device"))
{
_hostDevice = parameters.GetValue<DeviceInfoVM>("Device");
Title = $"串口连接配置 - {_hostDevice?.DeviceName}";
Config = new SerialPortConfigVM(_hostDevice?.SerialPortConfig);
}
else if (parameters.ContainsKey("Config"))
{
Config = new SerialPortConfigVM(parameters.GetValue<SerialPortConfigVM>("Config"));
}
RefreshPorts();
}
public override void OnDialogClosed()
{
_eventAggregator.GetEvent<OverlayEvent>().Publish(false);
}
#endregion
}
}